Multi Carrier Group Delay Measurement Application
Extension To 500MHz
Accessory License Dongle, For Software Licenses
Pulse Measurement Application
Vector Signal Analysis Application, For Modulation Analysis On Digital Modulated Single Carrier Signals
Accessory OFDM Vector Signal Analysis Software
Cord Power
Qty: 1Cable RF SMA(m) -SMA(m) 1 m
Qty: 2Dongle USB
Qty: 1SIM Card Serialized for FSPC K96 OFDM VSA Software
Qty: 1Cable Connecting RF B2000 SMA(m) - BNC(m) 36 in
Qty: 1Void- USB Drive with Software and Manuals
Qty: 11.85MM F-F ADAPTER
Qty: 1RF Preamplifier, 30dB, 100kHz To 67GHz
High Pass Filter, Improved Dynamic Range For Measurement Of Harmonics, Suppression Of Fundamental Signals From 500MHz To 1.5GHz
LO/IF Connections For External Mixers
OCXO, Precision Frequency Reference. Aging/Year : 0.35X10E-7 , Temperature Drift : 1X10E-9
Extension To 500MHz
Multi Carrier Group Delay Measurement Application
Noise Figure Measurement Application, Noise Source Required
Phase Noise Measurement Application
Vector Signal Analysis Application, For Modulation Analysis On Digital Modulated Single Carrier Signals
2GHz Analysis Bandwidth
Noise Power Ratio Measurement
Cord Power
Qty: 1Cable RF SMA(m) -SMA(m) 1 m
Qty: 2USB Drive with Software and Manuals
Qty: 11.85MM F-F ADAPTER
Qty: 1RF Preamplifier, 30dB, 100kHz To 67GHz
OCXO, Precision Frequency Reference. Aging/Year : 0.35X10E-7 , Temperature Drift : 1X10E-9
Extension To 512 MHz Signal Analysis Bandwidth
External Generator Control
2GHz Analysis Bandwidth
LO/IF Connections For External Mixers
Analog Base Band Inputs, Analysis Bandwidth 40MHz,
Resolution Bandwidth >10MHz, 20MHz And 50MHz Additionally
Noise Figure Measurement Application, Noise Source Required
Phase Noise Measurement Application
Measurement Application For Detection And Display Of Low Level Spurious Signals
Vector Signal Analysis Application, For Modulation Analysis On Digital Modulated Single Carrier Signals
High Pass Filter, Improved Dynamic Range For Measurement Of Harmonics, Suppression Of Fundamental Signals From 500MHz To 1.5GHz
Noise Power Ratio Measurement
Cord Power
Qty: 1Cable RF SMA(m) -SMA(m) 1 m
Qty: 2Cable Connecting RF B2000 SMA(m) - BNC(m) 36 in
Qty: 1USB Drive with Software and Manuals
Qty: 11.85MM F-F ADAPTER
Qty: 1Extension To 160MHz Signal Analysis Bandwidth, Includes Microwave Preselector Bypass
RF Preamplifier, 30dB, 100kHz To 67GHz
Noise Figure Measurement Application, Noise Source Required
Phase Noise Measurement Application
Modulation Analysis Application For Modulation Analysis Of Analog (AM, FM, PM) Modulated Single Carrier Signals
19" Adapter BW2010, Cabinet 5HU 1/1
Cord Power
Qty: 1Handle Kit 19 in ZZA-KN5
Qty: 1USB Drive with Software and Manuals
Qty: 11.85MM F-F ADAPTER
Qty: 1RF Preamplifier, 30dB, 100kHz To 67GHz
OCXO, Precision Frequency Reference. Aging/Year : 0.35X10E-7 , Temperature Drift : 1X10E-9
EMI Measurement Application For Diagnostics Of RF Interference With Spectrum Analyzers R&SFSW
Cord Power
Qty: 1FSW / FSWP MANUALS ON USB DRIVE
Qty: 11.85MM F-F ADAPTER
Qty: 1High Pass Filter, Improved Dynamic Range For Measurement Of Harmonics, Suppression Of Fundamental Signals From 500MHz To 1.5GHz
2GHz Analysis Bandwidth
LO/IF Connections For External Mixers
RF Preamplifier, 30dB, 100kHz To 67GHz
OCXO, Precision Frequency Reference. Aging/Year : 0.35X10E-7 , Temperature Drift : 1X10E-9
Phase Noise Measurement Application
Measurement Application For Detection And Display Of Low Level Spurious Signals
Pulse Measurement Application
Transient Measurement Application
Real-Time Spectrum Analyzer, 512 MHz Including 200 MHz IF Filter
Analog Base Band Inputs, Analysis Bandwidth 40MHz,
Power Amplifier And Envelope Tracking Measurement Application
Direct DPD Measurement Application
Noise Power Ratio Measurement
Noise Figure Measurement Application, Noise Source Required
Transient Measurements, Extension Chirp Analysis
Modulation Analysis Application For Modulation Analysis Of Analog (AM, FM, PM) Modulated Single Carrier Signals
Vector Signal Analysis Application, For Modulation Analysis On Digital Modulated Single Carrier Signals
Cord Power
Qty: 1Cable RF SMA(m) -SMA(m) 1 m
Qty: 2Cable Semi-Rigid Loopback BNC(m)-BNC(m)
Qty: 1Cable Connecting RF B2000 SMA(m) - BNC(m) 36 in
Qty: 2Adapter SMA(m) - SMA(m)
Qty: 1Power Splitter
Qty: 1USB Drive with Software and Manuals
Qty: 11.85MM F-F ADAPTER
Qty: 1Extension To 500MHz
Analog Base Band Inputs, Analysis Bandwidth 40MHz,
LO/IF Connections For External Mixers
OCXO, Precision Frequency Reference. Aging/Year : 0.35X10E-7 , Temperature Drift : 1X10E-9
Phase Noise Measurement Application
Cord Power
Qty: 1Cable RF SMA(m) -SMA(m) 1 m
Qty: 2Cable Semi-Rigid Loopback BNC(m)-BNC(m)
Qty: 1Cable Connecting RF B2000 SMA(m) - BNC(m) 36 in
Qty: 2void- USB Drive with Software and Manuals
Qty: 11.85MM F-F ADAPTER
Qty: 1Extension To 320MHz Signal Analysis Bandwidth
LO/IF Connections For External Mixers
RF Preamplifier, 30dB, 100kHz To 67GHz
OCXO, Precision Frequency Reference. Aging/Year : 0.35X10E-7 , Temperature Drift : 1X10E-9
Resolution Bandwidth >10MHz, 20MHz And 50MHz Additionally
Noise Figure Measurement Application, Noise Source Required
Phase Noise Measurement Application
Pulse Measurement Application
Modulation Analysis Application For Modulation Analysis Of Analog (AM, FM, PM) Modulated Single Carrier Signals
Vector Signal Analysis Application, For Modulation Analysis On Digital Modulated Single Carrier Signals
Cord Power
Qty: 1Cable RF SMA(m) -SMA(m) 1 m
Qty: 2USB Drive with Software and Manuals
Qty: 11.85MM F-F ADAPTER
Qty: 1RF Preamplifier, 30dB, 100kHz To 67GHz
Extension To 160MHz Signal Analysis Bandwidth, Includes Microwave Preselector Bypass
Noise Figure Measurement Application, Noise Source Required
Phase Noise Measurement Application
Modulation Analysis Application For Modulation Analysis Of Analog (AM, FM, PM) Modulated Single Carrier Signals
Cord Power
Qty: 1Cable RF SMA(m) -SMA(m) 1 m
Qty: 2Cable Connecting RF B2000 SMA(m) - BNC(m) 36 in
Qty: 1USB Drive with Software and Manuals
Qty: 11.85MM F-F ADAPTER
Qty: 1USB Drive with Software and Manuals
Qty: 11.85MM F-F ADAPTER
Qty: 1Void- USB Drive with Software and Manuals
Qty: 1Cable Semi-Rigid Loopback BNC(m)-BNC(m)
Qty: 1Void- USB Drive with Software and Manuals
Qty: 1Cable 9-Pin(m) - 9-Pin(m)
Qty: 1Cable Semi-Rigid Loopback BNC(m)-BNC(m)
Qty: 11.85MM F-F ADAPTER
Qty: 1High Pass Filter, Improved Dynamic Range For Measurement Of Harmonics, Suppression Of Fundamental Signals From 500MHz To 1.5GHz
Extension To 160MHz Signal Analysis Bandwidth, Includes Microwave Preselector Bypass
2GHz Analysis Bandwidth
LO/IF Connections For External Mixers
RF Preamplifier, 30dB, 100kHz To 67GHz
OCXO, Precision Frequency Reference. Aging/Year : 0.35X10E-7 , Temperature Drift : 1X10E-9
Analog Base Band Inputs, Analysis Bandwidth 40MHz,
Resolution Bandwidth >10MHz, 20MHz And 50MHz Additionally
Noise Figure Measurement Application, Noise Source Required
Phase Noise Measurement Application
Modulation Analysis Application For Modulation Analysis Of Analog (AM, FM, PM) Modulated Single Carrier Signals
WLAN 802.11Ad Measurement Application
Cable Connecting RF B2000 SMA(m) - BNC(m) 36 in
Qty: 1Cord Power
Qty: 1Cable RF SMA(m) -SMA(m) 1 m
Qty: 2USB Drive with Software and Manuals
Qty: 11.85MM F-F ADAPTER
Qty: 1USB Drive with Software and Manuals
Qty: 11.85MM F-F ADAPTER
Qty: 1Extension To 160MHz Signal Analysis Bandwidth, Includes Microwave Preselector Bypass
RF Preamplifier, 30dB, 100kHz To 67GHz
Noise Figure Measurement Application, Noise Source Required
Phase Noise Measurement Application
Measurement Application For Detection And Display Of Low Level Spurious Signals
Modulation Analysis Application For Modulation Analysis Of Analog (AM, FM, PM) Modulated Single Carrier Signals
19" Adapter BW2010, Cabinet 5HU 1/1
Handle Kit 19 in ZZA-KN5
Qty: 1Cord Power
Qty: 1USB Drive with Software and Manuals
Qty: 11.85MM F-F ADAPTER
Qty: 1Void- USB Drive with Software and Manuals
Qty: 11.85MM F-F ADAPTER
Qty: 1Rohde & Schwarz FSW Brochure
Content is AI-generated. Verify critical details with manufacturer-provided resources.
The R&S FSW67 spans 2 Hz to 67 GHz with DC coupling, or 10 MHz to 67 GHz with AC coupling. A high-performance YIG preselector ensures image-free measurements from 8 GHz upward throughout the millimeter-wave spectrum. The 0.01 Hz frequency resolution enables precise characterization of ultra-stable oscillators and synthesizers used in advanced radar, satellite communications, and 5G millimeter-wave systems.
The FSW67 covers the full 60 GHz ISM band with up to 2 GHz internal analysis bandwidth via the R&S FSW-B2001 option. With the optional R&S FSW-K95 measurement application, it provides a one-box solution for IEEE 802.11ad analysis with 2.16 GHz channel bandwidth support. For IEEE 802.11ay requiring up to 8.64 GHz bandwidth with four bonded channels, the R&S FSW-B5000 option combined with the FSW-K97 application enables complete channel bonding analysis.
With RF preamplifier off, RF attenuation at 0 dB, and YIG preselector on, the FSW67 achieves DANL of -146 dBm (typically -150 dBm) normalized to 1 Hz from 8 GHz to 13.6 GHz. From 13.6 GHz to 18 GHz, DANL is -144 dBm (typically -148 dBm), and from 18 GHz to 23 GHz it is -141 dBm (typically -145 dBm). At lower frequencies from 1 MHz to 1 GHz, DANL is -149 dBm (typically -154 dBm). Noise cancellation provides 13 dB improvement for frequencies up to 43 GHz and 8 dB from 43 GHz to 67 GHz.
The FSW67 offers scalable analysis bandwidth from 10 MHz standard to an exceptional 5 GHz maximum. Internal bandwidth options include 28 MHz, 40 MHz, 80 MHz, 160 MHz, 320 MHz, 512 MHz, 1200 MHz, and 2000 MHz. The R&S FSW-B5000 option extends to 5 GHz analysis bandwidth using an external R&S RTO2064 oscilloscope, making it possible to analyze ultra-wideband signals for 5G NR FR2, automotive radar, and advanced satellite communications.
With RF attenuation at 0 dB, YIG preselector on, RF preamplifier off, and two tones at -20 dBm each, the FSW67 delivers TOI greater than 8 dBm (typically 11 dBm) from 8 GHz to 13.6 GHz. From 13.6 GHz to 40 GHz, TOI exceeds 10 dBm (typically 15 dBm), ensuring excellent linearity throughout the standard millimeter-wave bands. Above 40 GHz through the 67 GHz upper frequency, nominal TOI is 12 dBm for accurate multi-carrier measurements.
Yes, the FSW67 provides real-time spectrum analysis up to 800 MHz bandwidth with the optional R&S FSW-B800R hardware. Real-time mode offers 0.46 microsecond probability of intercept and 2.4 million FFT per second processing capability. This enables seamless capture of transient signals, frequency-hopping waveforms, and intermittent interference throughout the full 67 GHz frequency range, with frequency mask triggers and automatic I/Q data capture for post-event analysis.
At a 1 GHz carrier, the FSW67 achieves SSB phase noise of -109 dBc (1 Hz) at 100 Hz offset (typically -116 dBc), better than -127 dBc (1 Hz) at 1 kHz offset (typically -132 dBc), and better than -139 dBc (1 Hz) at 100 kHz offset (typically -143 dBc). With the optional R&S FSW-B4 OCXO precision frequency reference, 10 Hz offset performance reaches -95 dBc (1 Hz) specified. This low phase noise enables accurate characterization of oscillators for radar and satellite applications.
Yes, the FSW67 excels at harmonic measurements across its full 67 GHz range. The second-harmonic intercept point reaches greater than 62 dBm (typically 70 dBm) for fundamental frequencies from 1.5 GHz to 4 GHz with YIG preselector on and RF preamplifier off. For fundamentals from 4 GHz to 42.5 GHz, SHI is 65 dBm nominal, enabling measurement of second harmonics up to the analyzer's 67 GHz upper frequency limit with excellent dynamic range and no external filtering required.